HD8000 Series (seven-level)
10kV/single machine 15MVA~51MVA, maximum supporting 3 parallel machines
Performance characteristics
Communication protocol & intelligent software
Customizable communication protocol
Fast debugging tool hopeInsight, for fast networking debugging
Internationally leading technology
High-power IGCT AC-DC-AC Frequency Control Device
Key Technologies and Application of High-power IGCT AC-DC-AC Frequency Control system
Strong adaptability
Strong power grid adaptability
Strong environmental adaptability
Single transmission, multi-transmission and parallel transmission supported
Water cooling
Excellent control performance
Fast torque dynamic response
Adaptive to an asynchronous induction motor, permanent magnet synchronous motor and electrically excited synchronous motor;
Two-quadrant and four-quadrant rectification schemes supported;
Motor synchronized by sections, meeting the requirements of high-speed regulation range for rolling mill and hoist;
Modular design
Modular design of key components
Only 30 minutes for disassembly and assembly of the power module; easy to maintain
Intelligent fault diagnosis system with fast positioning
Engineering reliability design
IGCT fault and diagnosis +bridge arm shoot-through protection technology
IP54 overall protection and redundancy design of key components
Use of Thyristor device IGCT that is applied in military and metallurgical industries
Use of a power device with a double-sided crimping structure Strong monitoring system
main parameters
HD8000AA30AA60

Basical

Rectification

Input voltage 10KV10KV
Input frquency 45Hz~66Hz
Overload 110%@rated current, 120%@rated current 60s
Efficiency ≥99%
Power factor ≥0.95 (Rated current, equipped with 2% AC input   reactor)
Protection overload protection, overheat protection, short   circuit protection, fault pre-judgment, etc .

PWM

Rectification

Input frquency 45Hz~66Hz
Overload 110%@rated current, 120%@rated current 60s
Efficiency ≥98.5%
Power factor adjustable (default 1)
Protection overload protection, overheat protection, short   circuit protection, fault pre-judgment, etc. 
InverterOutput voltage 10KV
Max output frequency 110Hz
Speed stable accuracy OLVC: 0.01%, CLVC: 0.01% OLVC: 0.01%, CLVC: 0.01%
Speed pulse OLVC: 0.2%, CLVC: 0.1% OLVC: 0.4%, CLVC: 0.2%
Start torque OLVC: 150%, CLVC: 200% OLVC: 130%, CLVC: 150%
Torque control V/F: Yes, OLVC: Yes, CLVC: Yes V/F: Yes, OLVC: Yes, CLVC: Yes
Torque accuracy OLVC: 5%, CLVC: 2%OLVC: 5%, CLVC: 2%
Torque response time OLVC: 5ms, CLVC: 5ms OLVC: 5ms, CLVC: 5ms
Rotating response time OLVC: 100ms, CLVC: 100ms OLVC: 150ms, CLVC: 150ms
Dynamic drop equivalent OLVC: 0.5%*s, CLVC: 0.25%*s OLVC: 1%*s, CLVC: 0.5%*s
Overload 110%@rated current, 120%@rated current 60s
EnvironmentTemperature inlet temperature ≤40
Altitude ≤4000m (2000m~4000m de-rating)

Mechanical

Data

IP protection IP54
Cooling Water cooling
Anti corrosion C4-M


download