| Model | HD8000 Series Medium-Voltage Engineering Inverter | |
| Basic rectifier | Input frequency | 45 Hz ~ 66 Hz |
| Fundamental power factor | ≥ 95% (based on 12-pulse and above, rated current, | |
| and 2% current input reactor) | ||
| PWM rectifier | Input frequency | 45 Hz ~ 66 Hz |
| Power factor | 1 (can be set continuously) | |
| Protection functions | Overload protection, overheating protection, short circuit protection, | |
| fault prediction | ||
| Inverter | Output voltage | 1: 1.65 kV; 2: 2.4 kV; 3: 3.3 kV; 4: 4.16 kV; 6: 6.6 kV; |
| A: 10 kV; B: 13.8 kV; C: 19.8 kV | ||
| Output frequency | 0 ~ 110 Hz (higher output frequencies can be customized as required) | |
| Speed stability | OLVC: 0.2% CLVC: 0.01% | |
| Speed fluctuation | OLVC: 0.4% CLVC: 0.2% | |
| Starting torque | OLVC: 150% CLVC: 200% | |
| Torque control | V/F: Supported OLVC: Supported CLVC: Supported | |
| Torque accuracy | OLVC: 5% CLVC: 2% (customizable) | |
| Torque response time | ≤ 5 ms | |
| Speed response time | OLVC: 100 ms CLVC: 100 ms | |
| Dynamic speed drop equivalent | OLVC: 0.5%*s CLVC: 0.25%*s | |
| System | Efficiency | Two-quadrant: ≥ 99% (excluding the rectifier transformer) |
| Four-quadrant: ≥98.5% (excluding the rectifier transformer) | ||
| Temperature | Water inlet temperature ≤ 35°C (external water) | |
| Altitude | ≤ 2000m (derating required for 2000m ~ 4000m) | |
| IP rating | IP54 | |
| Cooling mode | Liquid cooling | |
| Corrosion resistance class | C4-M | |