Air cooling AC/DC+DC/DC two-stage topology IGBT power supply
AC-DC/DC-DC two-stage topology hydrogen power supply (air cooling)
Performance characteristics
Wide Range of Voltage Regulation
Supports 0-900Vdc output
High Power Factor
Power factor>0.99, with reactive power compensation capability
Lower Harmonic
With harmonic suppression function, AC side Thdi≤3%, grid friendly
Power Grid Adaptability
Wide voltage, frequency adaptability,support low short-circuit ratio weak power grid operation
Strong Ability to Adapt to Environment
Air cooling heat dissipation, independent air duct design, high reliability
Modular Design
Easy maintenance, good parallel characteristics, easy system expansion
main parameters
ProductAC/DC+DC/DC Two-stage Topology Series
DC ParametersOutput Voltage Range0V~900V
Output Current RangeMeeting customized needs
DC Voltage Ripple≤1%
DC Stabilized Current Precision±0.5% (steady state)
DC Stabilized Voltage Precision±0.5% (steady state)
Load Response Time<0.1s (0%~100% load, running state)
Output Control ModeCurrent control (default), Voltage control, Power control
AC ParametersInput AC Voltage Range380V~690V
Rated Operating Frequency50Hz / 60Hz
Rated Power Factor>0.99 (over 30%Pn)
Adjustable Power Factor Range-0.95 Lead~0.95 Lag
Allowable Grid Frequency Deviation±10%
Allowable Grid Voltage Deviation±10%
Total HarmonicDistortion<3% (over 30%Pn)
Rate of Grid- connected Current
Access Method3-phase 3-wire+PE
SystemWiring in / Out modeMeeting customized needs
EfficiencyMaximum efficiency 97.5%
Environmental RequirementsCooling MethodTemperature-controlled air cooling
Working Temperature Range-40°C~+55°C
Electromagnetic Environment CategoryClass A
Relative Humidity0%~95% (no condensation)
Enclosure Protection RatingIP23
Highest Altitude of Installation Site4000m
External
Communication
External Communication InterfaceRS485, Ethernet and 4mA~20mA digital analog, etc.
External Communication ProtocolModbus RTU, Modbus TCP
DisplayHMITouch screen (optional)