900V/950V Full-Power Converter
1.5MW(Power Cabinet), 1.8MW(Power Cabinet), 2.2MW (Power Cabinet), 3.X~4.4MW, 4.X~6.6MW, 6.X~8.8MW, 9.X~13.0MW, 12.X~ 17.0MW, 18.X~26.0MW, 24.X~30MW
Performance characteristics
Mature Design
Hopewind has over 10 years of experience in the development and application of three-level systems, along with a mature supply chain. The product shares many similarities with the 690V system
Excellent Power Quality
The converter uses a three-level topology solution, with more output levels and lower harmonic content
Higher Efficiency
The efficiency is as high as 98% under rated conditions, greatly increasing the turbine’s power generation revenue
Better Cost-Effectiveness
With generator power design bottlenecks addressed and internal cable usage reduced within the turbine, the overall cost of the turbine system is lowered
Efficient O&M
Modular, lightweight, and standardized component design simplifies assembly and maintenance, reducing material and spare parts costs
Energy-saving Standby Mode
The energy-saving standby mode reduces losses during standby periods for both the converter and liquid cooling system, enhancing the owner's power generation revenue
Remote Monitoring and Intelligent Diagnosis
The remote network system of the converter can intelligently diagnose wind turbine faults
main parameters
Power1.5MW (Power Cabinet)1.8MW (Power Cabinet)2.2MW (Power Cabinet)3.X~4.4MW4.X~6.6MW6.X~8.8MW9.X~13.0MW12.X~17.0MW18.X~26.0MW24.X~30.0MW
Operating Voltage1026V~1254V2
Power Cabinets
Connected in Parallel
3
Power Cabinets
Connected in Parallel
4
Power Cabinets
Connected in Parallel
6
Power Cabinets
Connected in Parallel
8
Power Cabinets
Connected in Parallel
12
Power Cabinets
Connected in Parallel
16
Power Cabinets
Connected in Parallel
Grid-side Frequency47.5Hz~52.5Hz / 57Hz~63Hz
Grid-side Maximum Continuous Current900A1060A1300A
Grid-side Overload Current (1min/10min)990A1166A1430A
Generator-side Frequency1Hz~100Hz
Generator-side Maximum Continuous Current900A1060A1300A
Generator-side Overload Current (1min/10min)990A1166A1430A
Grid Voltage Harmonic Tolerance≤5%
Grid Voltage Imbalance Tolerance≤8%
System Efficiency≥98%
Noise<80dB
Operating TemperatureAmbient Temperature: –30℃ to +50℃; Liquid Inlet Temperature: +5℃ to +55℃ (50℃ to 55℃ derated)
Storage Temperature-40℃ to +70℃
AltitudeStandard Type: ≤3000m; Plateau Type: 3000m~5000m
Cooling ModeLiquid Cooling
Ingress ProtectionIP54
Fault Voltage Ride Through(FVRT)In compliance with the Wind Turbines -test Procedure of Voltage Fault Ride Through Capability
Dimensions (W*H*D) (mm)700*2200*650Size ASize BSize CSize D2*Size C/Size E2*Size D2*Size E

Hopewind power cabinets, distribution cabinets, and liquid cooling cabinets used in the low-voltage three-level full-power converter are all designed with standardized dimensions, allowing flexible layout combinations between cabinets.

The recommended dimensions for the 3.XMW~20.0MW converters are as follows:

Size A: 1400*2200*1300; Size B: 2100/1700*2200*1300; Size C: 2800/2400*2200*1300; Size D: 3500/3100*2200*1300; Size E: 4200*2200*1300


download