HBHV32 M1 Series Battery
Performance characteristics
Self-Consumption Optimization
Battery storage system balance the feeding and demands
Grid independence realization
Benefits from Peak Shaving
Store the power during off-peak and use the energy at peak-time
Save on the electricity bills by reducing peak demand
VPP Revenue
Manage the stability of clean electricity through cloud-based technology to maximum your revenue
Enabling a cost reduction, as well as boosting the system’s efficiency
main parameters
ModelHBHV32-S2-M1HBHV32-S3-M1HBHV32-S4-M1
System Data
Module Number in Pack234
Battery Capacity32.65 Ah
Total Energy6.68 kWh10.03 kWh13.38 kWh
Energy (Useable)6.31 kWh9.47 kWh12.63 kWh
Rated Voltage204.8 V307.2 V409.6 V
Output Voltage Range179~230 V268~345 V358~460 V
Operating Voltage Range185~227 V278~340 V371~454 V
Peak Discharge Current37.76 A @ 5s
Max. Charging / Discharging Power8.45 kW12.68 kW16.91 kW
General Parameters
Dimensions (W × D × H)780 × 176 × 860 mm780 × 176 × 1100 mm780 × 176 × 1360 mm
Weight86.6 kg120.5 kg154.4 kg
Ingress ProtectionIP65
Cooling SystemNatural cooling
Operating Altitude≤2000 m
Operating Ambient Humidity5%~95%
Calendar Life10 years (25℃), 15 years expandable
Cycle Life>6000 cycles (25℃, 60%SOH)


ModelHV Box (HCHV32-M1)Module (BMHV32-M1)
HBHV32-S2-M112
HBHV32-S3-M113
HBHV32-S4-M114


ModelBMHV32-M1
Nonimal Capacity33.25 Ah
Nonimal Energy3.40 kWh
Rated Capacity32.65 Ah
Rated Energy3.34 kWh2
Nonimal Voltage102.4 V
Output Voltage Range80.0~115.2 V
Shipment Voltage104.3~105.6 V
Dimensions (W × D × H)712 × 176 × 250 mm
Weight33.5 ± 1.0 kg
Ingress ProtectionIP65 (in stacked up status)
Operating Altitude≤2000 m
Connection32S1P
Communication between Module and HV BoxDaisy chain
InstallationFloor-mounted installation
Shipment Capacity25~30% SOC
Safety CertificationIEC 62619:2022


ModelHCHV32-M1
Operating Voltage Range100~750 V
Max. Input / Output Current32 A
Peak Input / Output Current37.76 A @ 5 s
Dimensions (W × D × H)712 × 176 × 300 mm
Weight14 ± 0.5 kg
Optimal Operating Temperature15~30℃
Operating Ambient Temperature-20~+55℃
Module Series Connection2~4S
Max. Rack Parallel Connection4P
Ingress ProtectionIP65 (in stacked up status)
Communication between HV Box and PCSCAN2.0 / RS485
Communication between HV Box and ModuleDaisy chain
Communication between HV BoxCAN2.0


download