| Model | HBHV32-S2-M1 | HBHV32-S3-M1 | HBHV32-S4-M1 |
| System Data | |||
| Module Number in Pack | 2 | 3 | 4 |
| Battery Capacity | 32.65 Ah | ||
| Total Energy | 6.68 kWh | 10.03 kWh | 13.38 kWh |
| Energy (Useable) | 6.31 kWh | 9.47 kWh | 12.63 kWh |
| Rated Voltage | 204.8 V | 307.2 V | 409.6 V |
| Output Voltage Range | 179~230 V | 268~345 V | 358~460 V |
| Operating Voltage Range | 185~227 V | 278~340 V | 371~454 V |
| Peak Discharge Current | 37.76 A @ 5s | ||
| Max. Charging / Discharging Power | 8.45 kW | 12.68 kW | 16.91 kW |
| General Parameters | |||
| Dimensions (W × D × H) | 780 × 176 × 860 mm | 780 × 176 × 1100 mm | 780 × 176 × 1360 mm |
| Weight | 86.6 kg | 120.5 kg | 154.4 kg |
| Ingress Protection | IP65 | ||
| Cooling System | Natural cooling | ||
| Operating Altitude | ≤2000 m | ||
| Operating Ambient Humidity | 5%~95% | ||
| Calendar Life | 10 years (25℃), 15 years expandable | ||
| Cycle Life | >6000 cycles (25℃, 60%SOH) | ||
| Model | HV Box (HCHV32-M1) | Module (BMHV32-M1) |
| HBHV32-S2-M1 | 1 | 2 |
| HBHV32-S3-M1 | 1 | 3 |
| HBHV32-S4-M1 | 1 | 4 |
| Model | BMHV32-M1 |
| Nonimal Capacity | 33.25 Ah |
| Nonimal Energy | 3.40 kWh |
| Rated Capacity | 32.65 Ah |
| Rated Energy | 3.34 kWh2 |
| Nonimal Voltage | 102.4 V |
| Output Voltage Range | 80.0~115.2 V |
| Shipment Voltage | 104.3~105.6 V |
| Dimensions (W × D × H) | 712 × 176 × 250 mm |
| Weight | 33.5 ± 1.0 kg |
| Ingress Protection | IP65 (in stacked up status) |
| Operating Altitude | ≤2000 m |
| Connection | 32S1P |
| Communication between Module and HV Box | Daisy chain |
| Installation | Floor-mounted installation |
| Shipment Capacity | 25~30% SOC |
| Safety Certification | IEC 62619:2022 |
| Model | HCHV32-M1 |
| Operating Voltage Range | 100~750 V |
| Max. Input / Output Current | 32 A |
| Peak Input / Output Current | 37.76 A @ 5 s |
| Dimensions (W × D × H) | 712 × 176 × 300 mm |
| Weight | 14 ± 0.5 kg |
| Optimal Operating Temperature | 15~30℃ |
| Operating Ambient Temperature | -20~+55℃ |
| Module Series Connection | 2~4S |
| Max. Rack Parallel Connection | 4P |
| Ingress Protection | IP65 (in stacked up status) |
| Communication between HV Box and PCS | CAN2.0 / RS485 |
| Communication between HV Box and Module | Daisy chain |
| Communication between HV Box | CAN2.0 |