Three-phase Hybrid Inverter
HYNV5/6/8/10/12K-G01
Performance characteristics
Flexible application
• Up to 20 A string current
• Support 210 mm & bifacial PV modules
• 100 ~ 800 V wide battery voltage range
Convenient installation
• All quick Plug and Play terminals
• Ergonomic handle
• WIFI + LAN connection for 24/7 monitoring
Superior performance
• 98.4% maximum conversion efficiency
• Support up to 3HP air conditioner black startup
• 100% three-phase unbalanced output
Safe & Reliable
• Integrated arc fault circuit interrupter (AFCI)
• IP66 ingress protection
• 4ms backup mode switching time
main parameters
ModelHYNV5K-G01HYNV6K-G01HYNV8K-G01HYNV10K-G01HYNV12K-G01
PV Input
Recommended Max. PV power7.5 kW9 kW12 kW15 kW18 kW
Max. PV Input Voltage1000 V
Operating Voltage Range140 — 950 V200 — 950 V
Startup Voltage180 V250 V
Rated Input Voltage600 V
Number of MPP Trackers2
Max. Input Number Per MPP Tracker1/12/1
Max. Input Current Per MPPT20/20 A27/20 A
Max. Short-circuit Current30/30 A40.5/30 A
Battery
Battery TypeLithium battery
Battery Voltage100 — 800 V
Max. Charge / Discharge Current30 A37 A
Max. Charge / Discharge Power5 kW6 kW8 kW10 kW12 kW
CommunicationCAN / RS485
AC Output (Grid)
Rated Output Power5 kW6 kW8 kW10 kW12 kW
Max. Apparent Output Power5.5 kVA6.6 kVA8.8 kVA11 kVA13.2 kVA
Rated Grid Voltage380 V / 400 V (3P + N + PE)
Rated Grid Frequency50 Hz / 60 Hz
Max. Output Current8.4 A10 A13.3 A16.7 A20 A
Power Factor>0.99 (0.8 leading — 0.8 lagging)
THDi<3% (at rated power)
AC Output (Backup)
Rated Output Power5 kW6 kW8 kW10 kW12 kW
Max. Apparent Output Power5.5 kVA6.6 kVA8.8 kVA11 kVA13.2 kVA
Back-up Switch Time4 ms
Rated Output Voltage380 V / 400 V (3P + N + PE)
Rated Frequency50 Hz / 60 Hz
THDv (Linear Load)<3%
AC Input (Grid)
Max. Input Power10 kW12 kW16 kW20 kW24 kW
Rated Input Current15.2 A18.2 A24.2 A30.3 A36.4 A
Rated Input Voltage380 V / 400 V (3P + N + PE)
Rated Input Frequency50 Hz / 60 Hz
Efficiency
Max. Efficiency98.0%98.4%
European Efficiency97.3%97.6%97.8%
Protection & Function
Grid MonitoringYes
AC Short-circuit ProtectionYes
DC Reverse Polarity ProtectionYes
DC Overcurrent Protection (Battery)Yes
DC Switch (PV)Yes
Surge ProtectionYes
Integrated AFCIYes
General Data
Topology (Solar / Battery)Transformerless /Transformerless
Dimensions (W × H × D)508 × 583 × 204 mm
Weight22 kg27 kg
Degree of ProtectionIP66
Operating Temperature Range-25 — +60 ℃
Operating Humidity Range0 — 100% (non-condensing)
Max. Operating Altitude3000 m
Cooling MethodNatural cooling
DisplayLED, APP, Web
CommunicationCAN / RS485
DC Connection TypeMC4
AC Connection TypePlug-and-play connector